35kV transformator napajanja na ulje
20000KVA 35KV
20000KVA 35KV
3150KVA 35KV
| Rated capacity (KVA) |
Voltage combination | Join group label | No-load loss (W) |
Load loss (W) |
Short-circuit impedance (%) |
No-load current (%) |
||
| High tension (KV) |
Tapoff % |
Low pressure (KV) |
||||||
| S13-50/35 | 38.5 35 |
±5 ±2x2.5 |
0.4 | Dyn11 Yyn0 |
128 | 1200/1140 | 6.5 | 1.30 |
| S13-100/35 | 184 | 2010/1910 | 1.10 | |||||
| S13-125/35 | 216 | 2370/2260 | 1.10 | |||||
| S13-160/35 | 224 | 2820/2680 | 1.00 | |||||
| S13-200/35 | 272 | 3320/3160 | 1.00 | |||||
| S13-250/35 | 320 | 3950/3760 | 0.95 | |||||
| S13-315/35 | 384 | 4750/4530 | 0.95 | |||||
| S13-400/35 | 464 | 5740/5470 | 0.85 | |||||
| S13-500/35 | 544 | 6910/6580 | 0.85 | |||||
| S13-630/35 | 664 | 7860 | 0.65 | |||||
| S13-800/35 | 784 | 9400 | 0.65 | |||||
| S13-1000/35 | 920 | 11500 | 0.65 | |||||
| S13-1250/35 | 1120 | 13900 | 0.60 | |||||
| S13-1600/35 | 1350 | 16600 | 0.60 | |||||
| S13-2000/35 | 1590 | 19700 | 0.55 | |||||
| S13-2500/35 | 1890 | 23200 | 0.55 | |||||
| Rated capacity (KVA) |
Join group label | Voltage combination | No-load current % |
No-load loss W |
Load loss (120℃)W |
Impedance voltage % |
||
|
High tension (KV) |
High-pressure tap range % |
Low pressure (KV) |
||||||
| SCB10-315/35 | Yyn0 or Dyn11 |
35 or 38.5 |
±5or ±2×2.5 |
0.4 3.15 6 6.3 10 10.5 11 |
2 | 1160 | 4170 | 6 7 8 9 |
| SCB10-400/35 | 2 | 1360 | 5360 | |||||
| SCBI10-500/35 | 2 | 1600 | 6590 | |||||
| SCB10-630/35 | 1.8 | 1840 | 7680 | |||||
| SCB10-800/35 | 1.9 | 2220 | 9350 | |||||
| SC810-1000/35 | 1.9 | 2640 | 10880 | |||||
| SCB10-1250/35 | 1.7 | 3090 | 12840 | |||||
| SCB10-1600/35 | 1.7 | 3650 | 15390 | |||||
| SCB10-2000/35 | 1.5 | 4200 | 18110 | |||||
| SCB10-2500/35 | 7.5 | 4800 | 21680 | |||||
| SCB10-3150/35 | 1.3 | 5000 | 24400 | |||||
| SC810-4000/35 | 1.3 | 6950 | 29330 | |||||
| SCB10-5000/35 | 1.1 | 8320 | 34770 | |||||
| SCB10-6300/35 | 1.1 | 9840 | 40630 | |||||
| SCB10-8000/35 | Yd11 or Ynd11 |
1 | 11200 | 45050 | ||||
| SCB10-10000/35 | 1 | 12800 | 51200 | 7 | ||||
| SC810-12500/35 | 0.9 | 16150 | 55300 | |||||
| SCB10-16000/35 | 0.8 | 19560 | 59800 | |||||
1. Proces projektiranja trafostanice: Fazni pristup Trafostanici od 110 kV trebalo je 16 mjeseci od koncepta...
ČITAJ VIŠEEnergetski transformator od 40 MVA isključuje diferencijalnu zaštitu nakon kvara bliskog dovoda. testovi ulja čist...
ČITAJ VIŠEŠto je transformator čvrstog stanja (SST)? Godine 2022., europski pilot-proizvod za elektroprivredu zamijeni...
ČITAJ VIŠEKriza nestašice transformatora: Zašto su nova postrojenja kritična Više od 80% velikih energetskih transform...
ČITAJ VIŠE